LK1600 User Manual Rev. 1
Enable LRC: enable LRC output for each track. If enabled, LRC will be sent as 2 hex
characters. Hex values A to F (10 to 15) are represented by characters : ; < - > and ?
respectively.
7. Enable Start Sentinel: enable individual track "start sentinel" output.
Enable Separator: enable individual track "field separator" output.
Enable End Sentinel: enable individual track "end sentinel" output.
8. Track Prefix: maximum 8 characters, sent before start sentinel of each track.
Track Field Terminator: 1 character, sent before field separators in each track.
Track Suffix: maximum 8 characters, sent after end sentinel of each track.
9. Click [OK] after finishing parameter edit. Write the template into the keyboard. Save the
template into a file for future reference and for programming multiple keyboards.
10. Verify MSR and keyboard output under Windows Notepad or the POS software.